========================== ELECTROMOTIVE WINTEC ========================== Release Notes --------------------- * Build 4.11.56 - 03/26/2021 - xdi200 has been given fuel pump timer option * Build 4.11.55 - 01/14/2021 - gets rid of error message for range checking gpio values inputed - adds tec ls gpio restriction, still needs to modified to only upload 5 - Fixes gpio dashboard box by only displaying active gpios * Build 4.11.52 - 11/13/2020 - Day/Night mode was throwing errors, fixed - Rev Limit was not updating the dashboard - Ego problems with specific unit using 2 values instead of a 10 point table. This was fixed on a previous update but never documented due to personel transition * Build 4.11.41 - 10/13/2018 - BUG: TECs200/TECgt200 loses GPO 3, 4, 5, and 6 when 2 wire IAC is selected. fixed. - New Ability to select HALL/MAG sensor for crank and CAM sensors on the TEC K (firmware is not ready yet for this feature [pending]). - Removed XDI2 firmware 5009 (Bricks units) and reverted to 5000 firmware. * Build 4.11.40 - 4/29/2018 - Incresed GPI Fuel Trim Gamma Correction range from -50-50% to -50-100%. - Fixed TEC3R engine type listing being different between the new configuration page and the general configuration page * Build 4.11.39 - 10/14/2017 - New enabled IAC on the XDI 200 * Build 4.11.37 - 7/26/2017 - BUG: MAF value showing incorrectly on the interface. fixed. * Build 4.11.36 - 4/15/2017 - BUG: XDI-2 200 Rev Limiter options not showing. fixed. * Build 4.11.35 - 4/2/2017 - BUG: TEC GT 200 IAC not working on GPO1. fixed. * Build 4.11.0 - 6/26/2015 - New electromotive company logos - New TEC K unit supported. - New Staged Method Secondary Supplements Primary - New auto-ve process and gradient-based equations - New MSComm has been replaced. Should fix a number of communication issues. - New optimize TOG feature. Modifies TOG based on the VE table values. - New Ability to start WinTEC through command line, "wintec4.exe binfile.WT4TGT" - New Ability to select and copy and paste table values - BUG: Corrected interpolation equation. fixed. - BUG: TEC 3 Internal datalog conversions corrected (GAMA). fixed. - BUG: Internal datalog EGO correction conversion on TEC 3, TEC GT, TEC M. fixed. - BUG: Datalog display tracer disappears upon leaving the screen. fixed. - BUG: Runtime error 91 list block. fixed. - BUG: A/F Ratio not saving on interpolate. fixed. - BUG: On 'Save As' option, Cancel caused an overwrite of file. fixed. - BUG: Table 'Setup' button has to be pressed twice to function. fixed. - BUG: Rev Limiter option returning to Full Coil Cut after change. fixed. - Firmware included in this version: TECgt - WTL0308000, TEC3 - WT30005002, TECs - WTS0005004, TECm - WTM0203005, TECk - WTK0001001 * Build 4.10.32 - 1/01/2015 - BUG: ACE3 not activating. fixed. * Build 4.10.26 - 6/27/2014 - BUG: Conversion of old .bin file to .wt4xx bin file yielded incorrect map sensor ID. This was caused by map sensor reordering in the db. fixed. - tables can be copy/pasted - Feature: Optional fixed injector pulsewidth (0 - 15ms) below a set RPM threshold (0-800RPM). - Firmware included in this version: TECgt - WTL0307004, TEC3 - WT30005002, TECs - WTS0005003, TECm - WTM0103004 * Build 4.10.25 - 6/11/2014 - BUG: Rare case of receiving incorrect default AFR value. fixed. - BUG: S19 Generation problem when converting negative numbers to ASCII HEX. fixed. * Build 4.10.24 - 6/10/2014 - BUG: TEC3 displayed map value not scaling properly. fixed. * Build 4.10.23 - 6/6/2014 - BUG: TECm and TECs program corruption: S19 length 120-130. fixed. - FW BUG: MAF Reading not showing up on dashboard. fixed. - FW BUG: PIC18 detection not working. fixed. PIC18 units now fully support TDC Offset of 1-58. - Firmware included in this version: TECgt - WTL0307003, TECs - WTS0005002, TECm - WTM0103003 * Build 4.10.21 - 5/30/2014 - BUG: TEC S Programming crash due to AFR division by zero. fixed. * Build 4.10.20 - 5/16/2014 - BUG: TPS Closed Throttle Error Margin incorrectly defaulting to off for older TEC M and TEC 3 files. fixed. - BUG: Primary advance showing additional degrees of advance on data recording. fixed. - Added more detailed information to upgrade dialog in how to choose the firmware file for unit upgrade. - BUG: RPM table calculation on new file not reaching upper limit. fixed. - RPM table values are now rounded off to whole numbers upon initial generation - BUG: Red dot on tables intermitently changing color under special circumstances. fixed. - BUG: ACE0 below 0.85 causes TPS delta enrichment to be constantly active. Minimum ACE0 changed from 0.75 to 0.85. - Prevention added from being able to set IAC minduty above maxduty. - BUG: EGO AFR, when AFR is set to something other than Gasoline, bin file will not upload to unit. fixed. - BUG: EGO AFR gauge corrected for all AFR values. fixed. - BUG: MAP Gauge Scaling misaligned when map sensor has a negative minimum value. fixed. - Introduced new default sensors - FW BUG: Indexing of tables. fixed. - Firmware included in this version: TEC3 - WT30005001 * Build 4.10.17 - 3/14/2014 - BUG: MAP Reading for older firmware was using a different conversion function. fixed. * Build 4.10.16 - 2/28/2014 - BUG: TECm Thermo Control not displaying edited values - BUG: Windows 7/Vista systems crashing while opening or saving datalog files Updated wintec410.pak to wintec410-01.pak * Build 4.10.15 - 2/24/2014 - BUG: Determining correct FW - BUG: TPS error margin crash - TPS fully closed throttle voltage values on different pages synchronized - BUG: data recording conversion from old 4.8 format caused some values to become out of place. fixed. - BUG: new configuration, custom sensor configuration crash. fixed. * Build 4.10.13 - 1/13/2014 - EGO Calibration interpolation function added - Barometric tables f2 quick help added - Removed dock 2D graphs option from options as it was unecessary - BUG: Old TEC3 Firmware malfunctioning with new bin file upload - Added warning to uploading new bin file to unit with older firmware as some functions do require the latest firmware for the given unit to function correctly - BUG: RunTime Error '713' Missing MSSTDFMT.DLL file added to deployment * Build 4.10.8 - 9/26/2013 - Changed default save location to 'My Documents' for configuration and datalog files. - Implemented auto-detect COM Port feature on main screen and in the options screen. - Selectable display and input of all temperature in Fahrenheit or Celsius - Added a notes section on the Advanced tab saving to the end of BIN files. - Upon start, WinTEC 4 checks for another instance already running and closes itself if found. - BUG: AutoVE correction beyond 50% prevented. - BUG: Dutycucle calculation for 3D Graph fixed. - BUG: Y-axis expansion upon re-open of 2D Graph fixed by replacement of graphing system. - TPS Fully closed voltage +0.08 correction is now adjustable. - Problem when selecting Progressive fuel cut - FIXED - MAP sensor range was .5v - 5v for the values the user could enter. The range is now 0-5v. - WARNING: Files saved with this version of WinTEC will NOT open in previous versions of WinTEC4. Files created in older versions will open without issue in this version. Customers should update to this version to open newer files. - Improved MAP resolution/accuracy for external dataloggers (requires latest firmware) - Added Alpha-N mode with Baro correction (MAP sensor becomes baro sensor, requires latest firmware) - AFR translation table now supports 4 ranges: Lambda, Gasoline AFR, Ethanol AFR, Methanol AFR - Function added that alerts the user to high coolant temp. Alert temperture is set in the WinTEc Control Panel. - New full table control features (right click): > Alternate axis variables (GPO Tables only, requires latest firmware) > Adjustable table dimensions (requires latest firmware) > Smooth, interpolate table values - Revised Flight Recorder datalog standard: delimited by tabs, new values recorded, Unit FW recorded, MAP units recorded - Added detailed view to dashboard - Standard graphs display on tuning pages, reactant to live data - Live data displays on tuning pages - New data collected and recorded from unit (MAP_Acc, TPS_Acc, SE0, SE1, ASE0, ASE1, ACE2, ACE3, ACE5, ACE6, ACE7, ACE8, DC4, DFC, FP, PW0, VE_Trim%, MAT_Trim%, CLT_Trim%, BARO_Trim%, EGO_Cor%) - Firmware included in this version: TECgt - WTL0307001, XDI-2 - WXD0205000, TEC3 - WT30005000, TECs - WTS0005000, TECm - WTM0103000